Portable Personal Security Grounding wire Earthing Equipment

The personal security grounding wire can be divided into low-voltage personal security wire and high-voltage personal security wire according to the voltage grade
The low-voltage grounding wire, also known as low-voltage short circuit grounding wire, low-voltage personal security wire and clamp type personal security wire, is mainly used for the secondary protection of low-voltage lines and lines higher than the line and electrical equipment during outage maintenance, to prevent the induced voltage injury in the maintenance line, providing a reliable guarantee for security inspectors.
Low voltage grounding wire is made of high-quality hot copper (or cooked aluminum) die-casting surface, polished and pressed. It is generally used to make three branch and four branch personal security lines. The personal security tongs are exquisite in technology and light in structure, and are suitable for personal security at the construction site.

Danh mục: Từ khóa: , , , , , , , , , , , , , , , , , , , , , ,

Mô tả

Portable Personal Security Grounding wire Earthing Equipment

Quick Details:

Place of Origin: China                                               Brand Name: XINCHENG

Product name: Personal security grounding wire Earthing equipment

Application: Safety protection                                   Conductor Type: Solid

Composition of personal security wire: personal security pliers, soft copper wire, copper nose, grounding clamp

Conductor Material: Pure Copper wire                       Type: insulated

Grounding wire:16-120mm2 or customized             Insulation Material: PVC

Color: Optional, The color of the connector can also be distinguished according to the customer’s requirements

Phase: single, three or four as requirement                Rated Voltage: 10KV/35KV/110KV/500KV 450KV/750KV

Handle of security pliers insulation material: Glass fiber reinforced plastic and Insulating rubber

Standard: IEC 60227                                                        Certification: ISO9001

Product description:

The personal security grounding wire is mainly used at the electrical operation site to avoid the harm of various induced voltages to operators. Type: Security wire can be divided into 3 phase type, 4 phase type and 5 phase type according to the number of phases used, and can be divided into short circuit type and short circuit grounding type according to the short circuit grounding type. The common specification of security line is 16 square meters.

Operating environment: – 25 ℃ to +55 ℃. Relative humidity ≤ 90%

The structural characteristics of the personal security wire (clamp type):

(1) It is composed of wire end clamp, short line, bus clamp, grounding wire, terminal lug, grounding terminal clamp or temporary grounding electrode and grounding rod.

(2) The clamps of the conductor end and the grounding end are made of high-quality aluminum alloy die-casting, and the metal of the supporting fasteners are nickel plated.

(3) The flat, bayonet, round grounding wire and the bus bar grounding wire in hand are made of advanced epoxy resin and glass fiber with excellent insulation performance and mechanical strength. At the same time, the operating handle is equipped with a silicone rubber sheath, which is firm, and the insulation is more safe and reliable.

(4) The short circuit wire and the grounding wire are twisted with multiple strands of high-quality soft copper wire, and are covered with a soft, high temperature resistant transparent insulating sheath, which can prevent the abrasion of grounding copper wire in use and ensure the safety of operators in operation.

(5) The new crimping process is adopted for the connection nose, bus clamp, grounding copper wire and outer sheath. The soft connection can effectively prevent the copper wire strand from breaking at the connection during use, and improve the reliability and service life of the grounding wire.

Classification:

The personal security grounding wire can be divided into low-voltage personal security wire and high-voltage personal security wire according to the voltage grade

The low-voltage grounding wire, also known as low-voltage short circuit grounding wire, low-voltage personal security wire and clamp type personal security wire, is mainly used for the secondary protection of low-voltage lines and lines higher than the line and electrical equipment during outage maintenance, to prevent the induced voltage injury in the maintenance line, providing a reliable guarantee for security inspectors.

Low voltage grounding wire is made of high-quality hot copper (or cooked aluminum) die-casting surface, polished and pressed. It is generally used to make three branch and four branch personal security lines. The personal security tongs are exquisite in technology and light in structure, and are suitable for personal security at the construction site.

The main components are composed of safety gear, jumper short circuit grounding tail wire, terminal lug, bus duct, grounding terminal clamp or five prevention locking clamp, grounding steel fiber and grounding operating rod. The grounding rod is made of glass fiber epoxy resin pipe with good mechanical strength and insulation performance as required. High quality hot copper (or cooked aluminum) die-casting surface is used for polishing and fastening connection with the wire nose. The conductor is a portable short circuit grounding wire.

Low voltage personal safety wire national standard wire clamp personal security ground wire

The grounding soft copper wire is made of high-purity oxygen-free copper wire with diameter of 0.2mm, multi stranded twisted into a cable, and wrapped with high-temperature heating plastic. The common specifications are 16mm2, 25mm2, 35mm2 and 50mm2. Can also be customized according to the needs of 70 square meters, 95 square meters, 120 square meters.

 

High voltage portable grounding equipment Personal line grounding safety Grounding safety ground wire:

Personal safety grounding wire is a grounding device installed to prevent induced voltage generated by adjacent live equipment and lines, so as to ensure the personal safety of operators.

The grounding hook is made of light aluminum alloy, and the pole body is made of light epoxy resin, which is very light. The length can be made according to your needs.

Working temperature of transparent PVC insulation protective sleeve: – 30 ℃– +55 ℃

Specification of pure copper grounding wire: 16mm2, 25mm2, 35mm2, 50mm2, 70mm2,95mm2, 120mm2, etc.; We can also produce according to your requirements.

 

1、 Composition of low-voltage personal security grounding wire:

Wire clamp: it is a wire connecting pliers;

Grounding wire: 4 * 1m+3m/piece, more than 25 mm2 strands of soft copper wire twisted into a strand, coated with a layer of transparent insulating PVC casing, 2 heads and 5 terminals are pressed onto the wire nose;

Grounding wire clamp: flat spiral grounding wire clamp or grounding wire pliers;

2、 Composition of lifting type personal security grounding wire:

Conductor clamp: it is a lifting type wire clamp;

Grounding wire: 8m/piece, 25mm2 multi strand soft copper wire twisted into a strand, coated with a layer of transparent insulating PVC casing, and crimped wire nose at two ends;

Grounding clamp: flat spiral grounding clamp;

High strength insulating rope: 8m/piece, one end of the rope is tied with a hook for easy hanging.

3、 Use of personal security grounding wire:

It is an auxiliary protection measure to prevent workers from being shocked by induced electricity when working on power cut lines, and to prevent accidental power intrusion when working on power distribution networks, so as to protect the personal safety of workers. It is suitable for indoor or outdoor rain free weather, and is suitable for various voltage levels, but the security wire must not replace the electrical inspection grounding.

Application:

The following three situations may occur during the construction and maintenance of outdoor lines and substations:

  1. Return current in the line
  2. Electrostatic induction generated by nearby charged objects
  3. The line is electrified due to the operator’s false closing

The grounding wire is to connect the lines that may be electrified with the earth to form a closed loop to ensure the personal safety of operators, so it is also called a safe return line.

Specifications parameters:

Specifications parameters:

Model Length Number Size of grounding wire Withstand Voltage
XC-JDX-1001 1.0m 3 rods/set 25 mm2 10KV
XC-JDX-3501 1.5m 3 rods/set 25 mm2 35KV
XC-JDX-6601 1.5m 3 rods/set 35 mm2 66KV
XC-JDX-11001 2.0m 3 rods/set 35 mm2 110KV
XC-JDX-22001 3.0m 3 rods/set 35 mm2 220KV
XC-JDX-33001 4.0m 3 rods/set 50 mm2 330KV
XC-JDX-50001 6.0m 3 rods/set 50 mm2 500KV

Remarks: We accept customization. For customization, please clarify the following information:

  1. There are two types of short circuit: split phase type and combined type. There are two types of wire end clamps, namely, flat mouth type and hook type. Please indicate when selecting.
  2. The sectional area and length of soft plastic copper wire are matched according to the specific requirements of users.
  3. When ordering, the specification range and voltage grade of the wire must be stated.
  4. The insulating operating rod shall be selected and matched according to the user’s requirements.
  5. The factory is equipped with special grounding electrodes, which can be selected by users according to their needs.

Grounding copper wire Parameter:

Cross sectional area / mm ² 10 16 25 35 50 70 95 120
Wire diameter / mm 4.2 5.7 7.5 8.78 11 12 16 17
Outer diameter / mm 7.3 7.8 9.6 11.2 12.6 16.5 21 22
Resistance value m Ω 1.98 1.24 0.79 0.56 0.4 0.28 0.21 0.16
Safe current carrying (a) 90 100 123 150 210 238 300 300

Use and maintenance of personal security line:

Before using the personal security line, the power supply should be checked to confirm that the power has been cut off, and it should be carried out after confirming that there is no voltage on the equipment. First, connect the grounding clamp to the grounding grid or flat iron piece, and then use the grounding rod to tighten the wire ends on the equipment wires. When removing the short circuit grounding wire, the sequence is exactly opposite to the above. The distance between the installed short circuit grounding wire and the live equipment shall not be less than the new value specified in the Electric Power Safety Work Regulations in consideration of the influence of the grounding wire swing. It is strictly prohibited to use winding method for grounding short circuit without wire clamp. Portable short circuit grounding wire shall be properly kept. Before each use, carefully check whether it is in good condition, the soft copper wire is not exposed, and the nut is not loose, otherwise it cannot be used. The inspection cycle of portable short circuit grounding wire is once every five years, and the inspection items are the same as factory inspection. The portable short circuit grounding wire passing the test shall be scrapped generally according to the size of short circuit current and visual inspection after being subjected to short circuit.

Usage and precautions:

  1. Ensure the integrity of the grounding wire, and store it in a special place with good ventilation and dry environment.
  2. The use of this grounding wire on electrical equipment shall comply with the relevant provisions of electrical safety work procedures.
  3. Before using the security wire, it is required to check the electricity and discharge, confirm that the electrical equipment has been cut off and hang the grounding wire before operation.
  4. The personal security wire is a security tool to protect the construction personnel from electric shock due to contact with the corresponding voltage. It cannot replace the portable short circuit grounding wire specified in SD332-89.
  5. Routine inspection shall be carried out for the security wire before use. It is prohibited to use the security wire in case of cracks, defects, poor contact, looseness of connecting parts, damage of insulating sheath and other defects

 

FAQ:

How long is your products warranty ?

A: The warranty period of our products is 18 months.

2 How about inspection?

A: We have the whole inspection system from raw material to end products include temperature test, strength test and so on.

3 What do you have for certificate?

A: Our products are passed through IEC60947and IEC60269standarded.

4 What is payment terms?

A: T.T, Western Union and L/C is acceptable.

5 What is the service offered by company?

A: We have the professional engineer team which can design and develop the mold to arrive different customer requirement.

We also have the sales team to offer good service from pre-sale to after-sale.

6 How to become the agents for JIUBAI?

A: It is OK! We will depend on the sales turn over and also do research on your market. If your have interest, let us discuss more !

Packaging & Delivery:

Packaging Details:

suitable packing for export. Economic Packing design which will save your transportation cost, or as customer requirements

1.Inside packing: Anti-moisture nylon bag + Carton box + woven belt.

2.Outside packing: carton box or wooden case and pallet.

3.According customer requirement.

Port: Shanghai, Qingdao, Tianjin

Lead Time : 7-15days

Please Contact Us:

 Miss: Lydia

https://fiberglasshotstick.com

E-mail:[email protected] 

WeChat : 86-13752439076   WhatsApp: 86-13752439076

Mob: 86-13752439076       Fax: 86-22-60863016     